CommandWeed Pressure Profile CommandDifficultyintermediateAdded2027.0Statusdraft

Weed Pressure Network Profile Command

Description:

Weeds a pressure network profile. All the vertices that are not at the pressure structures (fittings and appurtenances) are removed so the profile editing becomes much easier.

Location on Compact Ribbon:

Location on Extended Ribbon:

Instructions:

In the image below, the pressure structures are represented by a blue triangle. The structures that will be removed are marked with the red arrow:

  1. Run the command.

  2. Select a pressure pipe run profile in the profile view.

Result:

Notes:

  1. The vertices that are ± 0.1 m from the pressure structure are not removed because there were some drawings where the vertices were not aligned exactly with the pressure structure.

  2. This command only works in Civil 3D 2022 and newer.